CR 35 Bio - Hi Speed image plate scanner

Applications :

Phosphor Imager
Digital Radiography
Image plate scanning
Storage phosphor screens
Whole body radioluminography

General Description

CR 35 Bio is a compact high-speed scanner for all flexible types of image plates / storage phosphor screens up to the size of 35×43 cm. In combination with the corresponding imaging plate it can be used for a variety of different nuclides, such as H-3, C-11, C-14, F-18, P-32, P-33, S-35, Fe-59, Ga-68, Tc-99m, In-111, I-125, I-131, Cs-137, etc.

An integrated erasing unit allows to read and erase the imaging plate in one step.

Its novel design allows compact size and high speed scanning. The laser is focused to 30µm allowing pixels sizes from 30 to 200µm without pixel interpolation.

Features

red LED laser 635 nm

easy to use

high scanning speed

16bit dynamic range

integrated erasing unit

Ordering Information

22200002  CR 35 Bio
22200012  CR Reader software
22200015  CR 35 Dark Cabinet
08000206  external eraser IP's up to 35×43 cm

CR 35 Bio


Technical Data

Laser : red LED laser 635 nm focused to 30nm

Pixel size : 30 µm, 50 µm, 100 µm, 200 µm

size : 39×38×52 cm

weight : 21 kg

max. size for screens : 35cm width, length up to 43 cm or longer

interface : USB 2.0 high-speed

operating noise : <49db (A)

optional eraser : for high throughput and/or highly radioactive samples

data analysis : AIDA (network standalone) state-of-the-art data analysis optimized modules for TLC analysis gels and blots whole-body autoradiography GLP/GMP, 21 CFR part 11

 

HD-CR 35 Bio


Technical Data

Laser : red LED laser 635 nm focused to 12.5 µm

Pixel size : 12.5 µm, 25 µm, 50 µm, 100 µm, 200 µm

size : 39×38×52 cm

weight : 21 kg

max. size for screens : 35cm width, length up to 43 cm or longer

interface : USB 2.0 high-speed

operating noise : <49db (A)

optional eraser : for high throughput and/or highly radioactive samples

data analysis : AIDA (network standalone) state-of-the-art data analysis optimized modules for TLC analysis gels and blots whole-body autoradiography GLP/GMP, 21 CFR part 11

.............................................................................................................................................................................................